Put the QTC window's settings on its right-click menu
N1MM keeps them on a Setup tab inside the window; here they are a dialog behind a right-click, which suits a window this size better. Four of them, with N1MM's own defaults: how many QTCs a series carries, whether the RX Ready and Cfm steps are stopped at on the way through, and whether Hdr Agn and Agn clear what they are asking for again. Each one changes what the window does. The series count is passed to the search for contacts worth reporting, the two skip settings are the focus order, and the two clear settings are what the Agn buttons do. The Cfm buttons also disappear when a RTTY station is reading its own log out, which is what N1MM does with them. N1MM's remaining QTC settings are all about putting traffic on the air — the CW messages for Agn and TU, the field spacing, the four SSB recordings, the RTTY templates — and nothing here transmits, so they are left out rather than shown as settings that do nothing. The dialog says so where the operator will look. The right-click menu needed a background on the panel to come up anywhere but over a control: a panel with no background is not hit-tested. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
@@ -292,9 +292,16 @@ being worked, and never more than the ten any station may have — and cannot be
|
||||
edited. On CW and SSB the direction is fixed by the rules; on RTTY traffic goes
|
||||
both ways and the window has a switch.
|
||||
|
||||
Right-click the window for **Setup**: how many QTCs a series carries, whether
|
||||
the RX Ready and Cfm steps are stopped at, and whether Hdr Agn and Agn clear
|
||||
what they ask for again. The defaults are N1MM's — both steps skipped, the
|
||||
header cleared, the line left alone.
|
||||
|
||||
Nothing in the window transmits. On CW the operator sends from the entry window,
|
||||
on SSB by voice, and RTTY has no digital window yet, so Agn, Cfm and RX Ready
|
||||
move the cursor rather than putting anything on the air.
|
||||
move the cursor rather than putting anything on the air. N1MM's QTC settings for
|
||||
sending — the CW messages for Agn and TU, the field spacing, the SSB recordings
|
||||
and the RTTY templates — are left out with them.
|
||||
|
||||
The scoring was checked against six real WAE logs, and agrees with N1MM on
|
||||
points and on weighted multipliers to the contact.
|
||||
|
||||